{"id":37714,"date":"2014-04-10T00:00:59","date_gmt":"2014-04-09T22:00:59","guid":{"rendered":"http:\/\/www.cqdx.ru\/ham\/?p=37714"},"modified":"2023-09-24T16:10:54","modified_gmt":"2023-09-24T16:10:54","slug":"acom-2000a-new-rcu-acom-2000","status":"publish","type":"post","link":"https:\/\/www.cqdx.ru\/ham\/qro-qrp\/acom-2000a-new-rcu-acom-2000\/","title":{"rendered":"ACOM 2000A New RCU &#8211; Acom 2000"},"content":{"rendered":"<p>The new RCU is available as an option for all Acom 2000A amplifiers ever built!<\/p>\n<p><a href=\"https:\/\/www.cqdx.ru\/ham\/wp-content\/uploads\/2014\/03\/new_2000A_Controller_2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-37715\" alt=\"new_2000A_Controller_2\" src=\"https:\/\/www.cqdx.ru\/ham\/wp-content\/uploads\/2014\/03\/new_2000A_Controller_2.jpg\" width=\"581\" height=\"480\" srcset=\"https:\/\/www.cqdx.ru\/ham\/wp-content\/uploads\/2014\/03\/new_2000A_Controller_2.jpg 581w, https:\/\/www.cqdx.ru\/ham\/wp-content\/uploads\/2014\/03\/new_2000A_Controller_2-300x248.jpg 300w\" sizes=\"auto, (max-width: 581px) 100vw, 581px\" \/><\/a><\/p>\n<p>RCU Size: 167 x 130 x 25mm (6-2\/3&#8243; x 5-1\/8&#8243; x 1&#8243;) Only the Remote Control Unit needs to be placed near the operator. The main unit can be installed up to 3 meters (10 feet) away. RCU features include: amplifier status shown on LCD display, control of all functions, measuring and\/or monitoring of the 20 most important parameters, on-board technical assistance, troubleshooting suggestions, record of power-on hours, password provided.<\/p>\n<p>NOTE: All ACOM A2000 units come with the RCU unit. This is sold as as separate part or replacement.<\/p>\n<p><strong>SPECIFICATIONS:<\/strong><\/p>\n<p>\u2022 POWER SWITCH -&gt; OFF STATE:<br \/>\nHELP &#8211; to read serial numbers, power-on hours, suggestions<\/p>\n<p>\u2022 SET\/EXIT BUTON -&gt; OFF MENU<br \/>\nCALL SIGN \u2013 to change display message while in OFF-state<br \/>\nAUTO ANTENNA CHANGE \u2013 to select the logic of the antenna change<br \/>\nAUTO OPERATE \u2013 to select the behavior of the amplifier after a \u201csoft\u201d fault<br \/>\nSELF ADDRESS \u2013 to select the address of the amplifier if used in a network<br \/>\nCLEAR THE USER TUNINGS &#8211; to delete all USR-tunings<br \/>\nCLEAR THE MEMORY \u2013 to delete all stored data<\/p>\n<p>\u2022 ON\/OFF BUTTON -&gt; MAIN MENU -&gt; OPR\/STB BUTTON &#8211; to activate and use the amplifier.<br \/>\nAUTO TUNE &#8211; to match antennas (USR-tunings preparation)<\/p>\n<p>\u2022 SET\/EXIT BUTTON -&gt; MANUAL MODE &#8211;<br \/>\nMANUAL.TUNE &#8211; to match loads manually<br \/>\nMEASURE &#8211; to measure various amplifier operating parameters<br \/>\nSERVICE &#8211; to check motors&#8217; motion and tubes&#8217; zero-signal current<br \/>\nCAT SETTINGS \u2013 to tell the amplifier what transceiver is connected to it via CAT<\/p>\n<p>MORE SETTINGS<br \/>\n&#8211; LOCK \u2013 to protect the amplifier from unauthorized users<\/p>\n<div class=\"lyte-wrapper\" title=\"ACOM 2000A New RCU\" style=\"width:640px;max-width:100%;margin:5px auto;\"><div class=\"lyMe hidef\" id=\"WYL__q0UuMRcaNQ\"><div id=\"lyte__q0UuMRcaNQ\" data-src=\"https:\/\/i.ytimg.com\/vi\/_q0UuMRcaNQ\/hqdefault.jpg\" class=\"pL\"><div class=\"tC\"><div class=\"tT\">ACOM 2000A New RCU<\/div><\/div><div class=\"play\"><\/div><div class=\"ctrl\"><div class=\"Lctrl\"><\/div><div class=\"Rctrl\"><\/div><\/div><\/div><noscript><a href=\"https:\/\/youtu.be\/_q0UuMRcaNQ\" rel=\"nofollow\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/i.ytimg.com\/vi\/_q0UuMRcaNQ\/0.jpg\" alt=\"ACOM 2000A New RCU\" width=\"640\" height=\"340\" \/><br \/>Watch this video on YouTube<\/a><\/noscript><\/div><\/div><div class=\"lL\" style=\"max-width:100%;width:640px;margin:5px auto;\"><\/div>\n<p>Price: $799.95 USD<\/p>\n<p><a href=\"http:\/\/www.acom-bg.com\/amplifiers.html\" target=\"_blank\" rel=\"noopener\">Link<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The new RCU is available as an option for all Acom 2000A amplifiers ever built! RCU Size: 167 x 130 x 25mm (6-2\/3&#8243; x 5-1\/8&#8243; x 1&#8243;) Only the Remote Control Unit needs to be placed near the operator. The main unit can be installed up to 3 meters (10 feet) away. RCU features include:&hellip;<\/p>\n","protected":false},"author":2,"featured_media":37715,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"categories":[10],"tags":[],"class_list":["post-37714","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-qro-qrp","category-10","description-off"],"_links":{"self":[{"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/posts\/37714","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/comments?post=37714"}],"version-history":[{"count":0,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/posts\/37714\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/media\/37715"}],"wp:attachment":[{"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/media?parent=37714"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/categories?post=37714"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cqdx.ru\/ham\/wp-json\/wp\/v2\/tags?post=37714"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}